PV cell temperature range is 20 °C - 75 °C
JASA 250W PV modules and MICE0.25 micro-inverter are selected
Datasheet JASA PV module
Datasheet MICE family
Ns max abs = round down [Vmax abs mic inv] / [Voc max]
Ns max abs Maximum number of PV modules in series based on maximum absolute input voltage of micro-inverter
Vmax abs mic inv Maximum absolute input voltage of the micro-inverter
Voc max Maximum open circuit voltage of the PV module
Voc STC Open circuit voltage of the PV module at STC (V)
βVoc Temperature coefficient for open circuit voltage (% °C⁻¹ or % K⁻¹)
Tmod min Lowest module temperature (°C)
TSTC Module temperature at STC (°C), 25 °C
Ns max abs = round down [65/38.534] = round down [1.68] = 1 unit
It's safe to connect 1 unit of PV module in series per string for each micro-inverter. So, the micro-inverter wouldn't be damaged during OFF mode.
Design And Sizing of Grid-Connected Photovoltaic Power System - SEDA Malaysia- 4th Published 2023
Example 5.2