SOLARMAN 200W PV modules and SUNMAN 3.6 inverter are selected.
PV cell temperature range is 20 °C - 75 °C
SUNMAN Inverter Datasheet
SOLARMAN 200W PV Module Datasheet
7. to 10. are temperature coefficients.
f1 DC/AC ratio
Np Total PV modules in portrait per string (units)
Ns Total PV modules in series per string (units)
Pnominv Nominal power of the inverter (kW)
Pmax STC Peak power of PV module at STC
Nmppt Number of MPPT
From Step 10 Number of Strings per MPPT,
Np = 1
Ns = 11
From SOLARMAN 200W PV Module Datasheet --> Nominal or Rated power (AC part)
Pnominv = 3680 W
From SUNMAN Inverter Datasheet --> Nominal power (+/- 5%)
Pmax STC = 200 W
From SUNMAN Inverter Datasheet --> Number of independent MPPT inputs / String per MPPT input
Nmppt = 2 units
String = A series-connected group of solar panels
Number of independent MPPT inputs = 2
The inverter has 2 separate MPPT trackers.
MPPTs optimize the output of the PV strings they’re connected to independently of one another. This is especially helpful if you have different roof orientations, different shading conditions, or different string lengths.
String per MPPT input = A: 2 B: 2
MPPT "A" can accept up to 2 strings of panels wired in parallel.
MPPT "B" can also accept up to 2 strings of panels wired in parallel.
The new f1 will be closed to quetion given one.
For example in Step 1 Choose Inverter >> Step 1.4 >> With power clipping --> 1.11 < f1, f1 =1.19
If Nmppt = n,
MPPT [n-1] : [Np] *[ Ns ], DC/AC ratio = [f1]
MPPT [n] : [Np] * [Ns ], DC/AC ratio = [f1]
MPPT A : 1 * 11 , DC/AC ratio = 1.195
MPPT B : 1 * 11 , DC/AC ratio = 1.195
The schematic diagram in Malaysia must follow MS1837 standard, exp: MS 1837:2018
If can't identify single phase or 3 phase grids, may refer to the inverter data sheet.
Inverter AC output voltage > 400V consider high voltage, must use 3 phase grids.
Design And Sizing of Grid-Connected Photovoltaic Power System - SEDA Malaysia- 4th Published 2023
Example 4.12
Example 4.13
SEDA GCPV Tutorial Design - Nov 2024
2. Sizing with string or central inverter - Question 3
2. Sizing with string or central inverter - Question 4