SOLARMAN 200W PV modules and SUNMAN 3.6 inverter are selected.
PV cell temperature range is 20 °C - 75 °C
SUNMAN Inverter Datasheet
SOLARMAN 200W PV Module Datasheet
7. to 10. are temperature coefficients.
Np Total PV modules in portrait per string (units)
Ns Total PV modules in series per string (units)
Nt Total PV modules (units)
In this article, means per string, ≈ Nt per MPPT
Npmax per MPPT Maximum number of PV strings per MPPT (units)
If all options failed, reduce Ns, although it can't match Nt per mppt
If want to use all solar modules (Nt = Nt per mppt), choose another inverter.
Steps
1) Select Np which has Ns that are closest to Ns rec
2) Select Ns rec as Ns
Isc stc Short circuit current of the PV module datasheet at STC (A)
sf1 Safety factor. Typically 1.25 (decimal)
From SEDA GCPV course instructor, 1.25 is based on experience, doesn't have standard value.
Isc max MPPT MPPT maximum short circuit current rating of the MPPT in inverter datasheet (A)
Select single value, exp datasheet below show Isc max MPPT is 60 A, not 180 A (Total Isc max MPPT)
Nt per MPPT Total PV modules per MPPT (units)
Nt Total PV modules per inverter, in general can be Nt ac pwr in Step 1 Choose Inverter (units)
NMPPT Number of MPPT/ Numbe of MPPT trackers in inverter datasheet (units)
Select single value, exp datasheet below show NMPPT is 3 units, not 9 units (Total NMPPT)
Nt per MPPT = round down [22/2] = 11 modules per mppt
From Step 9 Inverter Maximum Efficiency , Ns rec = 12 or 13 units
From Step 8 Minimum Number of PV Modules Based on Inverter , Ns = 6 ... 15
Design And Sizing of Grid-Connected Photovoltaic Power System - SEDA Malaysia- 4th Published 2023
Example 4.11
SEDA GCPV Tutorial Design - Nov 2024
2. Sizing with string or central inverter - Question 3
2. Sizing with string or central inverter - Question 4
2. Sizing with string or central inverter - Question 5